info@allair.com 3116 Expressway Drive South, Islandia NY 11749 1-800-4-AllAir

STC Valves and Fittings

  • Home
  • STC Electronic Pneumatic Solenoid Valves

Electronic/Pneumatic Solenoid Valves

Cost-Effective Components for Reliable Flow and Pressure Control

STC’s high performance solenoid and air-pilot activated valves offer reliability, high-flow rates, compact and rugged designs, low power consumption, high-speed response, long life cycle, DIN connections with built-in surge suppression, and indicator lights. Numerous options, including built-in push-in fittings, manifolds, pre-wired electric connections, and namur valves are available. Installation, maintenance, and control are simple! For a list of functions for STC Solenoid Valves, check out the Solenoid Valve Guide at the bottom of this page.

Explore STC Valves, Fittings, and Air Control Products

Solenoid Valves

2P025-1/8 – 1/8″ NPT – Cv = 0.23 – 22 SCFM @ 100PSI
2P025-1/4 – 1/4″ NPT – Cv = 0.23 – 22 SCFM @ 100PSI
Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Electrical Connection: G = Grommet, D = DIN (with LED)
Port/Position/Solenoid: 2/2/1
Two Way, Direct Acting
Operating Temp: 14-140 deg. F
Operating Pressure: Vacuum – 115PSI
Response Time: <20ms
Power Rating: 3W for 40PSI, 4.8W for 60PSI, 6.5W for 115PSI

2V025-1/8 – 1/8″ NPT – Cv = 0.23 – 22 SCFM @ 100PSI
2V025-1/8 – 1/4″ NPT – Cv = 0.23 – 22 SCFM @ 100PSI
Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Electrical Connection: G = Grommet, D = DIN (with LED)
Port/Position/Solenoid: 2/2/1
Two Way, Direct Acting
Normally Closed
Operating Temp: 14-140 deg. F
Operating Pressure: Vacuum – 115PSI
Response Time: <20ms
Power Rating: 3W for 40PSI, 4.8W for 60PSI, 6.5W for 115PSI

2V035-1/8 – 1/8″ NPT – 10-32 Exh. – Cv = 0.055 SCFM @ 100PSIOrifice: 1mm
2V035-1/4 – 1/4″ NPT – 10-32 Exh. – Cv = 0.055 SCFM @ 100PSIOrifice: 1mm
Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Electrical Connection: G = Grommet, D = DIN (with LED)
Port/Position/Solenoid: 3/2/1
Three Way, Direct Acting
Normally Closed or Open
Operating Temp: 14-140 deg. F
Operating Pressure: Vacuum – 115PSI
Response Time: <20ms
Power Rating: 3W for 40PSI, 4.8W for 60PSI, 6.5W for 115PSI

2V1-1/8 – 1/8″ NPT – Cv = 0.23 – 22 SCFM @ 100PSI
Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Electrical Connection: G = Grommet, D = DIN (with LED)
Port/Position/Solenoid: 2/2/1
Two Way, Direct Acting
Normally Closed
Stacking
Operating Temp: 14-140 deg. F
Operating Pressure: Vacuum – 115PSI
Response Time: <20ms
Power Rating: 3W for 40PSI, 4.8W for 60PSI, 6.5W for 115PSI

3V1-1/8 – 1/8″ NPT – 10-32 Exh. – Cv = 0.055 SCFM @ 100PSIOrifice: 1mm
Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Electrical Connection: G = Grommet, D = DIN (with LED)
Port/Position/Solenoid: 3/2/1
Three Way, Direct Acting
Normally Closed or Open
Stacking
Operating Temp: 14-140 deg. F
Operating Pressure: Vacuum – 115PSI
Response Time: <20ms
Power Rating: 3W for 40PSI, 4.8W for 60PSI, 6.5W for 115PSI

Three Way, Two Position, Single Solenoid Valves (3/2/1)

3V110-1/8 – 1/8″ NPT – Cv = 0.67 – 25 SCFM @ 100PSI
3V210-1/4 – 1/4″ NPT – Cv = 0.89 – 53 SCFM @ 100PSI
3V310-1/4 – 1/4″ NPT – Cv = 1.68 – 80 SCFM @ 100PSI
3V310-3/8 – 3/8″ NPT – Cv = 1.68 – 80SCFM @ 100PSI
3V410-1/2 – 1/2″ NPT – Cv = 2.79 – 160SCFM @ 100PSI
Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Electrical Connection: G = Grommet, D = DIN (with LED)
Port/Position/Solenoid: 3/2/1
Three Way Valve
Two Position
Single Solenoid
Standard: Normally Closed (NC)
Operating Temp: 14-140 deg. F
Operating Pressure: 21 – 115PSI
Response Time: <20ms
Power Rating: 2.5W / 3W / 4.8W

Three Way, Two Position, Double Solenoid Valves (3/2/2)

3V120-1/8 – 1/8″ NPT – Cv = 0.67 – 25 SCFM @ 100PSI
3V220-1/4 – 1/4″ NPT – Cv = 0.89 – 53 SCFM @ 100PSI
3V320-3/8 – 3/8″ NPT – Cv = 1.68 – 80 SCFM @ 100PSI
3V420-1/2 – 1/2″ NPT – Cv = 2.79 – 160 SCFM @ 100PSI
Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Electrical Connection: G = Grommet, D = DIN (with LED)
Port/Position/Solenoid: 3/2/2
Three Way Valve
Two Position
Double Solenoid
Standard: Normally Closed (NC)
Operating Temp: 14-140 deg. F
Operating Pressure: 21 – 115PSI
Response Time: <20ms
Power Rating: 2.5W / 3W / 4.8W

Five Port, Four Way, Two Position, Single Solenoid Valves (5/2/1)

4V110-1/8 – 1/8″ NPT – Cv = 0.67 – 25 SCFM @ 100PSI
4V210-1/4 – 1/4″ (inlet/outlet) 1/8″ (exhaust) – Cv = 0.89 – 53 SCFM @ 100PSI
4V310-1/4 – 1/4″ (inlet/outlet) 1/4″ (exhaust) – Cv = 1.68 – 80 SCFM @ 100PSI
4V310-3/8 – 3/8″ (inlet/outlet) 1/4 (exhaust) – Cv = 1.68 – 80SCFM @ 100PSI
4V410-1/2 – 1/2″ NPT – Cv = 2.79 – 160SCFM @ 100PSI
Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Electrical Connection: G = Grommet, D = DIN (with LED)
Port/Position/Solenoid: 5/2/1
Four Way Valve
Operating Temp: 14-140 deg. F
Operating Pressure: 21 – 115PSI
Response Time: <20ms
Power Rating: 2.5W / 3W / 4.8W

Five Port, Four Way, Two Position, Double Solenoid Valves (5/2/2)

4V120-1/8 – 1/8″ NPT – Cv = 0.67 – 25 SCFM @ 100PSI
4V220-1/4 – 1/4″ (inlet/outlet) 1/8″ (exhaust) – Cv = 0.89 – 53 SCFM @ 100PSI
4V320-1/4 – 1/4″ (inlet/outlet) 1/4″ (exhaust) – Cv = 1.68 – 80 SCFM @ 100PSI
4V320-3/8 – 3/8″ (inlet/outlet) 1/4″ (exhaust) – Cv = 1.68 – 80 SCFM @ 100PSI
4V420-1/2 – 1/2″ NPT – Cv = 2.79 – 160 SCFM @ 100PSI
Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Electrical Connection: G = Grommet, D = DIN (with LED)
Port/Position/Solenoid: 5/2/2
Four Way Valve
Operating Temp: 14-140 deg. F
Operating Pressure: 21 – 115PSI
Response Time: <20ms
Power Rating: 2.5W / 3W / 4.8W

Five Port, Four Way, Three Position, Double Solenoid Valves (5/3/2)

4V130C-1/8 – 1/8″ NPT – Cv = 0.67 – 25 SCFM @ 100PSI
4V230C-1/4 – 1/4″ (inlet/outlet) 1/8″ (exhaust) – Cv = 0.89 – 53 SCFM @ 100PSI
4V330C-3/8 – 3/8″ (inlet/outlet) 1/4″ (exhaust) – Cv = 1.68 – 80 SCFM @ 100PSI
4V430C-1/2 – 1/2″ NPT – Cv = 2.79 – 160SCFM @ 100PSI
Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Electrical Connection: G = Grommet, D = DIN (with LED)
Port/Position/Solenoid: 5/3/2
Four Way Valve
Three Position
Double Solenoid
Operating Temp: 14-140 deg. F
Operating Pressure: 21 – 115PSI
Response Time: <20ms
Power Rating: 2.5W / 3W / 4.8W

Five Port, Four Way, Three Position, Double Solenoid Valves (5/3/2)

4V130E-1/8 – 1/8″ NPT – Cv = 0.67 – 25 SCFM @ 100PSI
4V230E-1/4 – 1/4″ (inlet/outlet) 1/8″ (exhaust) – Cv = 0.89 – 53 SCFM @ 100PSI
4V330E-3/8 – 3/8″ (inlet/outlet) 1/4″ (exhaust) – Cv = 1.68 – 80 SCFM @ 100PSI
4V430E-1/2 – 1/2″ NPT – Cv = 2.79 – 160 SCFM @ 100PSI
Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Electrical Connection: G = Grommet, D = DIN (with LED)
Port/Position/Solenoid: 5/3/2
Four Way Valve
Three Position
Double Solenoid
Operating Temp: 14-140 deg. F
Operating Pressure: 21 – 115PSI
Response Time: <20ms
Power Rating: 2.5W / 3W / 4.8W

Five Port, Four Way, Three Position, Double Solenoid Valves (5/3/2)

4V130P-1/8 – 1/8″ NPT – Cv = 0.67 – 25 SCFM @ 100PSI
4V230P-1/4 – 1/4″ (inlet/outlet) 1/8″ (exhaust) – Cv = 0.89 – 53 SCFM @ 100PSI
4V330P-3/8 – 3/8″ (inlet/outlet) 1/4″ (exhaust) – Cv = 1.68 – 80 SCFM @ 100PSI
4V430P-1/2 – 1/2″ NPT – Cv = 2.79 – 160SCFM @ 100PSI
Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Electrical Connection: G = Grommet, D = DIN (with LED)
Port/Position/Solenoid: 5/3/2
Four Way Valve
Three Position
Double Solenoid
Pressure Center
Operating Temp: 14-140 deg. F
Operating Pressure: 21 – 115PSI
Response Time: <20ms
Power Rating: 2.5W / 3W / 4.8W

Five Port, Four Way, Two Position, Single Solenoid NAMUR Valves (5/2/1)

4V210-1/4B – 1/4″ (inlet) 1/8″ (exhaust) – Cv = 0.8953 SCFM @ 100PSI
4V310-1/4B – 1/4″ (inlet) 1/4″ (exhaust) – Namur – Cv = 1.68 – 80 SCFM @ 100PSI
4V310-3/8B – 3/8″ (inlet) 1/4″ (exhaust) – Namur – Cv = 1.68 – 80 SCFM @ 100PSI
Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Electrical Connection: G = Grommet, D = DIN (with LED), E = Explosion Proof Coil, IS = Intrinsically Safe (24VDC Only)
Port/Position/Solenoid: 5/2/1
Four Way Valve
Two Position
Single Solenoid
Actuator Mount (NAMUR)
Operating Temp: 14-140 deg. F
Operating Pressure: 21 – 115PSI
Response Time: <20ms
Power Rating: 3W / 4.8W

Pilot Operated Air Valves: Body Ported Type

3 Way 2 Position Single Pilot Air Valve

3A110-1/8 – 1/8″ NPT – Cv = 0.67 – 25 SCFM @ 100PSI
3A210-1/4 – 1/4″ NPT – Cv = 0.78 – 53 SCFM @ 100PSI
3A310-3/8 – 3/8″ NPT – Cv = 1.68 – 80 SCFM @ 100PSI
3A410-1/2 – 1/2″ NPT – Cv = 2.79 – 160 SCFM @ 100PSI
# Ways/Port/Position/Pilot: 3/3/2/1
Operating Pressure: Valve: 0 – 115PSI, Pilot: 40PSI

3 Way 2 Position Double Pilot Air Valve

3A120-1/8 – 1/8″ NPT – Cv = 0.67 – 25 SCFM @ 100PSI
3A220-1/4 – 1/4″ NPT – Cv = 0.78 – 53 SCFM @ 100PSI
3A320-3/8 – 3/8″ NPT – Cv = 1.68 – 80 SCFM @ 100PSI
3A420-1/2 – 1/2″ NPT – Cv = 2.79 – 160 SCFM @ 100PSI
# Ways/Port/Position/Pilot: 3/3/2/2
Operating Pressure: Valve: 0 – 115PSI, Pilot: 40PSI

4 Way 2 Position Single Pilot Air Valve

4A110-1/8 – 1/8″ NPT – Cv = 0.67 – 25 SCFM @ 100PSI
4A210-1/4 – 1/4″ (inlet/outlet) 1/8″(exhaust) – Cv = 0.78 – 53 SCFM @ 100PSI
4A310-3/8 – 3/8″ (inlet/outlet) 1/4″ (exhaust) – Cv = 1.68 – 80 SCFM @ 100PSI
4A410-1/2 – 1/2″ NPT – Cv = 2.79 – 160 SCFM @ 100PSI
# Ways/Port/Position/Pilot: 4/5/2/1
Operating Pressure: Valve: 0 – 115PSI, Pilot: 40PSI

4 Way 2 Position Double Pilot Air Valve

4A120-1/8 – 1/8″ NPT – Cv = 0.67 – 25 SCFM @ 100PSI
4A220-1/4 – 1/4″ (inlet/outlet) 1/8″ (exhaust) – Cv = 0.78 – 53 SCFM @ 100PSI
4A320-3/8 – 3/8″ (inlet/outlet 1/4″ (exhaust) – Cv = 1.68 – 80 SCFM @ 100PSI
4A420-1/2 – 1/2″ NPT – Cv = 2.79 – 160 SCFM @ 100PSI
# Ways/Port/Position/Pilot: 4/5/2/2
Operating Pressure: Valve: 0 – 115PSI, Pilot: 40PSI

4 Way 3 Position Closed Center Double Pilot Air Valve

4A130C-1/8 – 1/8″ NPT – Cv = 0.67 – 25 SCFM @ 100PSI
4A230C-1/4 – 1/4″ (inlet/outlet) 1/8″(exhaust) – Cv = 0.78 – 53 SCFM @ 100PSI
4A330C-3/8 – 3/8″ (inlet/outlet) 1/4″ (exhaust) – Cv = 1.68 – 80 SCFM @ 100PSI
4A430C-1/2 – 1/2″ NPT – Cv = 2.79 – 160 SCFM @ 100PSI
# Ways/Port/Position/Pilot: 4/5/3/2 Closed Center
Operating Pressure: Valve: 0 – 115PSI, Pilot: 40PSI

4 Way 3 Position Exhausted Center Double Pilot Air Valve

4A130E-1/8 – 1/8″ NPT – Cv = 0.67 – 25 SCFM @ 100PSI
4A230E-1/4 – 1/4″ (inlet/outlet) 1/8″ (exhaust) – Cv = 0.78 – 53 SCFM @ 100PSI
4A330E-3/8 – 3/8″ (inlet/outlet 1/4″ (exhaust) – Cv = 1.68 – 80 SCFM @ 100PSI
4A430E-1/2 – 1/2″ NPT – Cv = 2.79 – 160 SCFM @ 100PSI
# Ways/Port/Position/Pilot: 4/5/3/2 Pressure Center
Operating Pressure: Valve: 0 – 115PSI, Pilot: 40PSI

4 Way 3 Position Pressure Center Double Pilot Air Valve

4A130P-1/8 – 1/8″ NPT – Cv = 0.67 – 25 SCFM @ 100PSI
# Ways/Port/Position/Pilot: 4/5/3/2 Exhaust Center
Operating Pressure: Valve: 0 – 115PSI, Pilot: 40PSI

Integrated Aluminum Base Mounted Manifolds

3V-100M

Port Size (NPT): 1/8″
No. Stations: 2, 4, 6, 8 or 16
Integrated Base for Mounting 3V-100 & 3A-100 Series Solenoid Valves
(Includes Mounting hardware and seal)

3V-200M

Port Size (NPT): 1/4″
No. Stations: 2, 4, 6, 8 or 16
Integrated Base for Mounting 3V-200 & 3A-200 Series Solenoid Valves
(Includes Mounting hardware and seal)

3V-300M

Port Size (NPT): 3/8″
No. Stations: 2, 4, 6, 8 or 16
Integrated Base for Mounting 3V-300 & 3A-300 Series Solenoid Valves
(Includes Mounting hardware and seal)

3V-400M

Port Size (NPT): 1/2″
No. Stations: 2, 4, 6, 8 or 16
Integrated Base for Mounting 3V-400 & 3A-400 Series Solenoid Valves
(Includes Mounting hardware and seal)

3V-100M-B

Blank Plate for 3V-100M Manifold

3V-200M-B

Blank Plate for 3V-200M Manifold

3V-300M-B

Blank Plate for 3V-300M Manifold

3V-400M-B

Blank Plate for 3V-400M Manifold

3V-100M-KIT

Blank Plate, Gasket, & Mounting Screws Set for 3V-100M Manifold

 
 

3V-200M-KIT

Blank Plate, Gasket, & Mounting Screws Set for 3V-200M Manifold

 
 

3V-300M-KIT

Blank Plate, Gasket, & Mounting Screws Set for 3V-300M Manifold

 
 

3V-400M-KIT

Blank Plate, Gasket, & Mounting Screws Set for 3V-400M Manifold

 
 

4V-100M

Port Size (NPT): 1/8″
No. Stations: 2, 4, 6, 8 or 16
Integrated Base for Mounting 4V-100 & 4A-100 Series Solenoid Valves
(Includes Mounting hardware and seal)

4V-200M

Port Size (NPT): 1/4″
No. Stations: 2, 4, 6, 8 or 16
Integrated Base for Mounting 4V-200 & 4A-200 Series Solenoid Valves
(Includes Mounting hardware and seal)

4V-300M

Port Size (NPT): 3/8″
No. Stations: 2, 4, 6, 8 or 16
Integrated Base for Mounting 4V-300 & 4A-300 Series Solenoid Valves
(Includes Mounting hardware and seal)

4V-400M

Port Size (NPT): 1/2″
No. Stations: 2, 4, 6, 8 or 16
Integrated Base for Mounting 4V-400 & 4A-400 Series Solenoid Valves
(Includes Mounting hardware and seal)

4V-100M-B

Blank Plate for 4V-100M Manifold

4V-200M-B

Blank Plate for 4V-200M Manifold

4V-300M-B

Blank Plate for 4V-300M Manifold

4V-400M-B

Blank Plate for 4V-400M Manifold

4V-100M-KIT

Blank Plate, Gasket, & Mounting Screws Set for 4V-100M Manifold

4V-200M-KIT

Blank Plate, Gasket, & Mounting Screws Set for 4V-200M Manifold

4V-300M-KIT

Blank Plate, Gasket, & Mounting Screws Set for 4V-300M Manifold

4V-400M-KIT

Blank Plate, Gasket, & Mounting Screws Set for 4V-400M Manifold

Solenoid Coils

100C

Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Elecrical Connection: D = DIN (with LED indicator and conduit connector)
Power Rating: 2.5W
For 100 Series Solenoid Valves
Insulation: F Class, IP65
Duty Cycle: 100% ED
CE Certification

100C

Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Elecrical Connection: G = Grommet
Power Rating: 2.5W
For 100 Series Solenoid Valves
Insulation: F Class, IP65
Duty Cycle: 100% ED
CE Certification

200C

Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Elecrical Connection: D = DIN (with LED indicator and conduit connector)
Power Rating: 3W, 4.8W, 6.5W
For 200-400 Series Solenoid Valves
Insulation: F Class, IP65
Duty Cycle: 100% ED
CE Certification

200C

Voltage:
1 = 12VDC
2 = 24VDC
2A = 24VAC
3 = 110VAC
4 = 220VAC (50/60Hz)
Elecrical Connection: G = Grommet
Power Rating: 3W, 4.8W, 6.5W
For 200-400 Series Solenoid Valves
Insulation: F Class, IP65
Duty Cycle: 100% ED
CE Certification

200C

Voltage:
1-E = 12VDC
2-E = 24VDC
3-E = 110VAC
4-E = 220VAC (50/60Hz)
Elecrical Connection: 1/2″ NPT conduit connection & 24″ Three-Strand Wires
ATEX Explosion Proof Coil for Models: 2P025, 2V025, 3P010, 2S012-020, 3S012, 2V130-250, 3V200-400, 4V200-400
(Valve Body is Not Included)
  
IP65, Class F Insulation, 100% Duty Cycle
DC = 4.5W (12VDC) / 4.6W (24VDC); AC = 6.8VA
1/2″ NPT Conduit Connection with 24″ Three-Strand Wires
RoHS Compliant

CSA 202633 Certificate Specifications:
Class I, Div 1, Groups A, B, C, & D
Class I, Div 2, Groups A, B, C, & D
Class II, Groups E, F, & G; Class III

FM 3006713 Certificate Specifications:
Class I, Div 1, Groups A, B, C, D, T4, Ta = 60°C
Encapsulation/Exp. Class I, Zone 1, AEx m II T4, Ta = 60°C
Dust-Ignition Class II/III, Div 1, Groups E, F, & G, T4, Ta = 60°C
Nonincendive Class I, Div 2, Groups A, B, C, D, T4, Ta = 60°C
Suitable for Class II, II, Div 2, Groups E, F, G, T4, Ta = 60°C

200C

Voltage:
1-ATEX = 12VDC
2-ATEX = 24VDC2A-ATEX = 24VAC
3-ATEX = 110VAC
4-ATEX = 220VAC (50/60Hz)
Elecrical Connection: DIN 43650B Connection with 10ft 3-Wired Cable & Sleeve
ATEX Explosion Proof Coil for Models: 2P025, 2V025, 3P010, 2S012-020, 3S012, 2V130-250, 3V200-400, 4V200-400
(Valve Body is Not Included)
  
ATEX Explosion Proof Coil
Ex II 2 G Ex mb IIC T4Gb
Ex 2 D EX mb tb IIIC T130°C Db
IP65, Class F Insulation, 100% Duty Cycle
Max. Media Temp. 176°F (180°C)
Ambient Temp: -4 to 122°F (-20 to 50°C)
RoHS Compliant

200C

Voltage: 2-IS-(3/2) = 24VDC
Elecrical Connection: DIN 43650B Connection, Includes Armature Tube Assembly (must be intact for IS rating)
Intrinsically Safe Coil for Models: 3V200-400, 4V200-400
(Valve Body is Not Included)
  
Intrinsically Safe Coil
Approved T5
CL. I; GR. A, B, C and D
CL. II; GR. E, F and G
CL. III; Div. 1 Hazardous Location
24VDC, 0.05A; U Max. 28V; I ≤ 115mA; P≤ 1.6W
T Amb. = 50°C (max); 100%ED
RoHS Compliant

Pneumatic Valve Specifications

Valve Type Port & Mounting Action & Motion Operating Pressure Coil Insulation & Protection Class Coil Duty Cycle Manual Override Electrical Connection Working Medium Maximum Pressure Operating Temperature Body Material Seal Material Lubrication Service
3A & 4A 100-400 Series Valves Body Ported, Manifold Mounted Air Pilot, Spool Design 0 to 115 PSI N/A 100% ED N/A N/A 40 micron filtered air or inert gas 180 PSI @ 75 Deg. F 14 to 140 Deg. F (-10 to 60 Deg. C) 6061-T6 Aluminum NBR (Buna N) Not Required Air
3V & 4V 100-400 Series Valves Body Ported, Manifold Mounted Internal Pilot, Spool Design 21 to 115 PSI F Class, IP65 (CE Certification) 100% ED Non-Locking: 100 series;
Locking: 200 to 400 series
D = DIN (with LED indicator, conduit terminal), G = Grommet (12″ – 18″ Lead Wire) 40 micron filtered air or inert gas 180 PSI @ 75 Deg. F 14 to 140 Deg. F (-10 to 60 Deg. C) 6061-T6 Aluminum NBR (Buna N) Not Required Air
2V025-035, 2P025 Series Valves Body Ported, Stacking or Manifold Mounted Direct Acting Vacuum to 115 PSI F Class, IP65 (CE Certification) 100% ED Non-Locking D = DIN (with LED indicator, conduit terminal), G = Grommet (12″ – 18″ Lead Wire) 40 micron filtered air, inert gas & liquid, non-corrosive liquid 180 PSI @ 75 Deg. F 14 to 140 Deg. F (-10 to 60 Deg. C) 6061-T6 Aluminum (Engineered Plastic for 2P Series) NBR (Buna N) Not Required Air
2V1, 3V1 Series Valves Body Ported, Stacking or Manifold Mounted Direct Acting Vacuum to 115 PSI F Class, IP65 (CE Certification) 100% ED Non-Locking D = DIN (with LED indicator, conduit terminal), G = Grommet (12″ – 18″ Lead Wire) 40 micron filtered air, inert gas & liquid, non-corrosive liquid 180 PSI @ 75 Deg. F 14 to 140 Deg. F (-10 to 60 Deg. C) 6061-T6 Aluminum NBR (Buna N) Not Required Air

Solenoid Valve Guide

Valve Configurations Functions
2 Way Valve Configuration: 2 Position Valve to turn on and off
3 Way Valve Configuration: 2 Position Valve to fully extend single acting cylinder (spring return cylinder)
4 Way Valve Configuration: 2 Position Valve to fully extend and retract double acting cylinder
4 Way Valve Configuration: 3 Position, Closed-Center Valve to stop a double acting cylinder in partial stroke, all ports are shut off
4 Way Valve Configuration: 3 Position, Exhaust-Center Valve to have both cylinder ports open to exhaust such that the cylinder can be extended and retracted manually to facilitate set-up
4 Way Valve Configuration: 3 Position, Pressure-Center Valve to stop a double acting cylinder in partial stroke with pressure on both ends of the cylinder

Have a Challenge? Let’s Find the Right Automation Solution.

Need help replacing a component, improving machine performance, or choosing the right product for your application? All Air Inc. helps customers solve pneumatic automation, motion control, sensing, machine safety, robotics, and industrial equipment challenges with trusted manufacturer partnerships, technical product knowledge, and responsive application support.

Need to speak with someone now? Call us.

1-800-4-AllAir